Quantcast
Channel: SCN: Message List - ABAP Connectivity
Browsing all 3125 articles
Browse latest View live

Re: SM58: "Out of range: size 5 exceeded max size limit 5.""

Hello Werner What is the message type? Is it inbound idoc? Regards,Tp

View Article


Re: SM58: "Out of range: size 5 exceeded max size limit 5.""

Regenerate the inbound function module assigned and check. Regards,Tp

View Article


Re: SM58: "Out of range: size 5 exceeded max size limit 5.""

Hi; Message type: ORDRSP|It's for Outbound (PO iDOC sent from SAP to external system).Do you mean "Activate IDOC_INBOUND_ASYNCHRONOUS" (i.e. SE37 and Ctrl +F3)? Regards

View Article

Re: SM58: "Out of range: size 5 exceeded max size limit 5.""

Hello Werner, IDOC_OUTPUT_ORDRSP is the function module which creates outbound idocs of message type ORDRSP. Inside the function module we have below user exits. check in the user exits whether there...

View Article

BAPI to upload data from internal table to BAPI input parameters

Hi Experts Is there any FM or BAPI to take data from internal table to input parameters of a BAPI? Thanks & regards,Akriti

View Article


Re: The BACK RFC destination can't be checked

Hi Manuel, Check the authorization S_RFC_ACL and S_RFC in both users.or Delete and re-create the back rfc. Regards,V Srinivasan

View Article

Re: The BACK RFC destination can't be checked

Did you read some documentation likeGive the users which RFC connections to the managed systems want to use, the appropriate authorization in the managed systems and in the Solution Manager system....

View Article

Re: IDOC Serialization EDIDC-SERIAL

Hello, Please review note 752194 for more information on this.Please also have a look at the chapter in SAP Library(ALE introduction and administration -> Administration of ALE functions->...

View Article


Image may be NSFW.
Clik here to view.

Re: Proxy Cliente - Connectivity WSDL error

Hi Alessio Thanks for your replies.I have successfully created the SAP WS and abap consumer program.But when I run the ABAP WS consumer program I get below logon screen: Then I cant proceed. Do you...

View Article


Re: Proxy Cliente - Connectivity WSDL error

Hi In The meantime I got rid of the WebLogic Logon screen.But now I face the runtime exception in the WS consumer program "SYSTEM ERROR SOAP: 1007 SRT: Unsupported xstream found: (HTTP Code 200: OK")...

View Article

Re: Proxy Cliente - Connectivity WSDL error

Hi Kim , have you try to contaci the Sap Systems Engineer , I think it should be enabled external calls.Regards

View Article

Re: Proxy Cliente - Connectivity WSDL error

Hi AlessioI will do that soon. Any proposal where to do that?Regards Kim

View Article

Testing RFC Destination..

Is there a Tcode or Program to test all the RFC Destination in one attempt from a SAP Box? Instead of testing them one by one in SM59?

View Article


Re: Testing RFC Destination..

Hi Try below Report : RSRFCPINFM: RFC_PING You might need to write a program to do it for all RFCs. Regards,Murthy

View Article

Re: LSMW question

a quick look into help.sap.com  or into my blog LSMW Material master by BAPI method - Part 1 would immediately answer your question

View Article


Re: Creating 2 idocs from every line of a file

Hello Fabio, As I understand, the file is converted into IDOC's in XI system right? I am tagging the below community, I guess they are aware about it. Process Integration (PI) & SOA Middleware...

View Article

Re: Creating 2 idocs from every line of a file

Yes Thanga,is right.Scenario is File-->XI-->IDOC.Fabio

View Article


Re: Proxy Cliente - Connectivity WSDL error

Finally, I got it to works! Thanks and regardsKim BrandtNTT DATA

View Article

Re: Proxy Cliente - Connectivity WSDL error

Hi Alession Sometimes output-valid is true and sometimes it is false checked for the same VAT no?When false no name and address is returned.That's strange. The same happen on EU's own web-page that...

View Article

Re: Proxy Cliente - Connectivity WSDL error

Hi Kim, Some times when the Server is busy you will get valid = 0. In this case therre will not be any Details about Company. Try to Output an error message when System exception occurs i.e. Server...